site logo

ວິທີການເລືອກ inverter thyristor ສໍາລັບ furnace melting induction?

How to choose inverter thyristor for induction melting furnace?

1) ເລືອກຕາມລະດັບຄວາມຖີ່ຂອງການດໍາເນີນງານຂອງ induction melting furnace;

The frequency is 100HZ—500HZ and the selected turn-off time is 20µs-45µs KK type thyristor.

The frequency is 500HZ—1000HZ and the selected turn-off time is 18μs-25μs KK type thyristor.

The frequency is 1000HZ—2500HZ and the selected turn-off time is 12μs-18μs KK type thyristor.

KKG-type thyristor with a frequency of 2500HZ—4000HZ and a selected turn-off time of 10µs-14µs.

The frequency is 4000HZ—8000HZ, and the selected turn-off time is 6μs—9μs KA type SCR.

2) ເລືອກຕາມພະລັງງານຜົນຜະລິດຂອງ furnace melting induction;

According to the theoretical calculation of the parallel bridge inverter circuit, the current flowing through each thyristor is 0.455 times the total current. Considering that enough space is left, a thyristor with the same size as the rated current is usually selected.

thyristor ປັດຈຸບັນ 300A/1400V ທີ່ເລືອກທີ່ມີພະລັງງານລະຫວ່າງ 50KW ແລະ 100KW. (ແຮງດັນໄຟຟ້າໄລຍະ 380V)

thyristor ປັດຈຸບັນ 500A / 1400V ທີ່ເລືອກທີ່ມີພະລັງງານ 100KW-250KW. (ແຮງດັນໄຟຟ້າໄລຍະ 380V)

thyristor 800A / 1600V ໃນປັດຈຸບັນທີ່ເລືອກທີ່ມີພະລັງງານຕັ້ງແຕ່ 350KW ຫາ 400KW. (ແຮງດັນໄຟຟ້າໄລຍະ 380V)

thyristor ປັດຈຸບັນ 1500A/1600V ທີ່ເລືອກທີ່ມີພະລັງງານລະຫວ່າງ 500KW ແລະ 750KW. (ແຮງດັນໄຟຟ້າໄລຍະ 380V)

thyristor ປັດຈຸບັນ 1500A/2500V ທີ່ເລືອກທີ່ມີພະລັງງານລະຫວ່າງ 800KW ແລະ 1000KW. (ແຮງດັນໄຟຟ້າໄລຍະ 660V)

thyristor ປັດຈຸບັນ 2000A / 2500V ທີ່ເລືອກທີ່ມີພະລັງງານ 1200KW-1600KW. (ແຮງດັນໄຟຟ້າໄລຍະ 660V)

thyristor ປັດຈຸບັນ 2500A/3000V ທີ່ເລືອກທີ່ມີພະລັງງານລະຫວ່າງ 1800KW ແລະ 2500KW. (ແຮງດັນໄຟຟ້າໄລຍະ 1250V)