Bagaimana memilih thyristor inverter untuk tungku peleburan induksi?
How to choose inverter thyristor for tungku peleburan induksi?
1) Pilih sesuai dengan rentang frekuensi operasi tungku peleburan induksi;
The frequency is 100HZ—500HZ and the selected turn-off time is 20µs-45µs KK type thyristor.
The frequency is 500HZ—1000HZ and the selected turn-off time is 18μs-25μs KK type thyristor.
The frequency is 1000HZ—2500HZ and the selected turn-off time is 12μs-18μs KK type thyristor.
KKG-type thyristor with a frequency of 2500HZ—4000HZ and a selected turn-off time of 10µs-14µs.
The frequency is 4000HZ—8000HZ, and the selected turn-off time is 6μs—9μs KA type SCR.
2) Pilih sesuai dengan daya keluaran tungku peleburan induksi;
According to the theoretical calculation of the parallel bridge inverter circuit, the current flowing through each thyristor is 0.455 times the total current. Considering that enough space is left, a thyristor with the same size as the rated current is usually selected.
Thyristor 300A/1400V yang dipilih saat ini dengan daya antara 50KW dan 100KW. (tegangan fase-in 380V)
Thyristor 500A/1400V arus yang dipilih dengan kekuatan 100KW-250KW. (tegangan fase-in 380V)
Thyristor 800A/1600V arus yang dipilih dengan daya mulai dari 350KW hingga 400KW. (tegangan fase-in 380V)
Thyristor 1500A/1600V yang dipilih saat ini dengan daya antara 500KW dan 750KW. (tegangan fase-in 380V)
Thyristor 1500A/2500V yang dipilih saat ini dengan daya antara 800KW dan 1000KW. (tegangan fase-in 660V)
Thyristor 2000A/2500V arus yang dipilih dengan kekuatan 1200KW-1600KW. (tegangan fase-in 660V)
Thyristor 2500A/3000V yang dipilih saat ini dengan daya antara 1800KW dan 2500KW. (tegangan fase-in 1250V)