Si të zgjidhni tiristorin inverter për furrën e shkrirjes me induksion?
How to choose inverter thyristor for furra e shkrirjes me induksion?
1) Zgjidhni sipas gamës së frekuencës së funksionimit të furrës së shkrirjes me induksion;
The frequency is 100HZ—500HZ and the selected turn-off time is 20µs-45µs KK type thyristor.
The frequency is 500HZ—1000HZ and the selected turn-off time is 18μs-25μs KK type thyristor.
The frequency is 1000HZ—2500HZ and the selected turn-off time is 12μs-18μs KK type thyristor.
KKG-type thyristor with a frequency of 2500HZ—4000HZ and a selected turn-off time of 10µs-14µs.
The frequency is 4000HZ—8000HZ, and the selected turn-off time is 6μs—9μs KA type SCR.
2) Zgjidhni sipas fuqisë dalëse të furrës së shkrirjes me induksion;
According to the theoretical calculation of the parallel bridge inverter circuit, the current flowing through each thyristor is 0.455 times the total current. Considering that enough space is left, a thyristor with the same size as the rated current is usually selected.
Tiristori aktual i zgjedhur 300A/1400V me fuqi midis 50KW dhe 100KW. (Tensioni i hyrjes në faza 380V)
Tiristori aktual i zgjedhur 500A/1400V me fuqi 100KW-250KW. (Tensioni i hyrjes në faza 380V)
Tiristori aktual i zgjedhur 800A/1600V me një fuqi që varion nga 350KW në 400KW. (Tensioni i hyrjes në faza 380V)
Tiristori aktual i zgjedhur 1500A/1600V me fuqi midis 500KW dhe 750KW. (Tensioni i hyrjes në faza 380V)
Tiristori aktual i zgjedhur 1500A/2500V me fuqi midis 800KW dhe 1000KW. (Tensioni i hyrjes në faza 660V)
Tiristori aktual i zgjedhur 2000A/2500V me fuqi 1200KW-1600KW. (Tensioni i hyrjes në faza 660V)
Tiristori aktual i zgjedhur 2500A/3000V me fuqi midis 1800KW dhe 2500KW. (Tensioni i hyrjes në faza 1250V)