- 06
- Apr
كيفية اختيار العاكس الثايرستور لفرن الصهر التعريفي؟
How to choose inverter thyristor for فرن الصهر التعريفي؟
1) حدد وفقًا لنطاق تردد التشغيل لفرن الصهر التعريفي ؛
The frequency is 100HZ—500HZ and the selected turn-off time is 20µs-45µs KK type thyristor.
The frequency is 500HZ—1000HZ and the selected turn-off time is 18μs-25μs KK type thyristor.
The frequency is 1000HZ—2500HZ and the selected turn-off time is 12μs-18μs KK type thyristor.
KKG-type thyristor with a frequency of 2500HZ—4000HZ and a selected turn-off time of 10µs-14µs.
The frequency is 4000HZ—8000HZ, and the selected turn-off time is 6μs—9μs KA type SCR.
2) اختر وفقا لطاقة الإخراج من فرن الصهر التعريفي ؛
According to the theoretical calculation of the parallel bridge inverter circuit, the current flowing through each thyristor is 0.455 times the total current. Considering that enough space is left, a thyristor with the same size as the rated current is usually selected.
الثايرستور 300A / 1400V المحدد الحالي بطاقة تتراوح بين 50KW و 100KW. (جهد طور 380 فولت)
الثايرستور 500A / 1400V المحدد بقوة 100KW-250KW. (جهد طور 380 فولت)
الثايرستور 800A / 1600V الحالي المحدد بقوة تتراوح من 350KW إلى 400KW. (جهد طور 380 فولت)
الثايرستور 1500A / 1600V المحدد الحالي بطاقة تتراوح بين 500KW و 750KW. (جهد طور 380 فولت)
الثايرستور 1500A / 2500V المحدد الحالي بطاقة تتراوح بين 800KW و 1000KW. (جهد طور 660 فولت)
الثايرستور 2000A / 2500V المحدد بقوة 1200KW-1600KW. (جهد طور 660 فولت)
الثايرستور 2500A / 3000V المحدد الحالي بطاقة تتراوح بين 1800KW و 2500KW. (جهد طور 1250 فولت)