induction အရည်ပျော်မီးဖိုအတွက် အင်ဗာတာ thyristor ကိုဘယ်လိုရွေးချယ်မလဲ။
How to choose inverter thyristor for induction အရည်ပျော်မီးဖို?
1) induction အရည်ပျော်မီးဖို၏လည်ပတ်မှုကြိမ်နှုန်းအကွာအဝေးအရရွေးချယ်ပါ။
The frequency is 100HZ—500HZ and the selected turn-off time is 20µs-45µs KK type thyristor.
The frequency is 500HZ—1000HZ and the selected turn-off time is 18μs-25μs KK type thyristor.
The frequency is 1000HZ—2500HZ and the selected turn-off time is 12μs-18μs KK type thyristor.
KKG-type thyristor with a frequency of 2500HZ—4000HZ and a selected turn-off time of 10µs-14µs.
The frequency is 4000HZ—8000HZ, and the selected turn-off time is 6μs—9μs KA type SCR.
2) induction အရည်ပျော်မီးဖို၏ output ပါဝါအရရွေးချယ်ပါ။
According to the theoretical calculation of the parallel bridge inverter circuit, the current flowing through each thyristor is 0.455 times the total current. Considering that enough space is left, a thyristor with the same size as the rated current is usually selected.
300KW နှင့် 1400KW ကြားပါဝါရှိသော 50A/100V thyristor ကို ရွေးချယ်ထားသည်။ (380V အဆင့်-ဗို့အား)
500KW-1400KW ပါဝါရှိသော 100A/250V thyristor ကို ရွေးချယ်ထားသည်။ (380V အဆင့်-ဗို့အား)
800KW မှ 1600KW အထိ ပါဝါရှိသော 350A/400V thyristor ကို ရွေးချယ်ထားသည်။ (380V အဆင့်-ဗို့အား)
1500KW နှင့် 1600KW ကြားပါဝါရှိသော 500A/750V thyristor ကို ရွေးချယ်ထားသည်။ (380V အဆင့်-ဗို့အား)
1500KW နှင့် 2500KW ကြားပါဝါရှိသော 800A/1000V thyristor ကို ရွေးချယ်ထားသည်။ (660V အဆင့်-ဗို့အား)
2000KW-2500KW ပါဝါရှိသော 1200A/1600V thyristor ကို ရွေးချယ်ထားသည်။ (660V အဆင့်-ဗို့အား)
2500KW နှင့် 3000KW ကြားပါဝါရှိသော 1800A/2500V thyristor ကို ရွေးချယ်ထားသည်။ (1250V အဆင့်-ဗို့အား)