site logo

انڊڪشن پگھلڻ واري فرنس لاءِ انورٽر thyristor ڪيئن چونڊيو؟

How to choose inverter thyristor for انڊڪشن پگھلڻ واري فرنس؟

1) انڊڪشن پگھلڻ واري فرنس جي آپريٽنگ فریکوئنسي رينج جي مطابق چونڊيو؛

The frequency is 100HZ—500HZ and the selected turn-off time is 20µs-45µs KK type thyristor.

The frequency is 500HZ—1000HZ and the selected turn-off time is 18μs-25μs KK type thyristor.

The frequency is 1000HZ—2500HZ and the selected turn-off time is 12μs-18μs KK type thyristor.

KKG-type thyristor with a frequency of 2500HZ—4000HZ and a selected turn-off time of 10µs-14µs.

The frequency is 4000HZ—8000HZ, and the selected turn-off time is 6μs—9μs KA type SCR.

2) انڊڪشن پگھلڻ واري فرنس جي آئوٽ پاور جي مطابق چونڊيو؛

According to the theoretical calculation of the parallel bridge inverter circuit, the current flowing through each thyristor is 0.455 times the total current. Considering that enough space is left, a thyristor with the same size as the rated current is usually selected.

منتخب ٿيل موجوده 300A / 1400V thyristor 50KW ۽ 100KW جي وچ ۾ طاقت سان. (380V مرحلي ۾ وولٹیج)

منتخب ٿيل موجوده 500A/1400V thyristor 100KW-250KW جي طاقت سان. (380V مرحلي ۾ وولٹیج)

منتخب ٿيل موجوده 800A/1600V thyristor 350KW کان 400KW تائين جي طاقت سان. (380V مرحلي ۾ وولٹیج)

منتخب ٿيل موجوده 1500A / 1600V thyristor 500KW ۽ 750KW جي وچ ۾ طاقت سان. (380V مرحلي ۾ وولٹیج)

منتخب ٿيل موجوده 1500A / 2500V thyristor 800KW ۽ 1000KW جي وچ ۾ طاقت سان. (660V مرحلي ۾ وولٹیج)

منتخب ٿيل موجوده 2000A/2500V thyristor 1200KW-1600KW جي طاقت سان. (660V مرحلي ۾ وولٹیج)

منتخب ٿيل موجوده 2500A / 3000V thyristor 1800KW ۽ 2500KW جي وچ ۾ طاقت سان. (1250V مرحلي ۾ وولٹیج)