site logo

इंडक्शन मेल्टिंग फर्नेस के लिए इन्वर्टर थाइरिस्टर कैसे चुनें?

How to choose inverter thyristor for प्रेरण पिघलने भट्ठी?

1) प्रेरण पिघलने वाली भट्ठी की ऑपरेटिंग आवृत्ति रेंज के अनुसार चयन करें;

The frequency is 100HZ—500HZ and the selected turn-off time is 20µs-45µs KK type thyristor.

The frequency is 500HZ—1000HZ and the selected turn-off time is 18μs-25μs KK type thyristor.

The frequency is 1000HZ—2500HZ and the selected turn-off time is 12μs-18μs KK type thyristor.

KKG-type thyristor with a frequency of 2500HZ—4000HZ and a selected turn-off time of 10µs-14µs.

The frequency is 4000HZ—8000HZ, and the selected turn-off time is 6μs—9μs KA type SCR.

2) इंडक्शन मेल्टिंग फर्नेस की आउटपुट पावर के अनुसार चयन करें;

According to the theoretical calculation of the parallel bridge inverter circuit, the current flowing through each thyristor is 0.455 times the total current. Considering that enough space is left, a thyristor with the same size as the rated current is usually selected.

चयनित वर्तमान 300A/1400V थाइरिस्टर 50KW और 100KW के बीच की शक्ति के साथ। (380V चरण-इन वोल्टेज)

चयनित वर्तमान 500A/1400V थाइरिस्टर 100KW-250KW की शक्ति के साथ। (380V चरण-इन वोल्टेज)

800KW से 1600KW तक की शक्ति के साथ चयनित वर्तमान 350A/400V थाइरिस्टर। (380V चरण-इन वोल्टेज)

चयनित वर्तमान 1500A/1600V थाइरिस्टर 500KW और 750KW के बीच की शक्ति के साथ। (380V चरण-इन वोल्टेज)

चयनित वर्तमान 1500A/2500V थाइरिस्टर 800KW और 1000KW के बीच की शक्ति के साथ। (660V चरण-इन वोल्टेज)

चयनित वर्तमान 2000A/2500V थाइरिस्टर 1200KW-1600KW की शक्ति के साथ। (660V चरण-इन वोल्टेज)

चयनित वर्तमान 2500A/3000V थाइरिस्टर 1800KW और 2500KW के बीच की शक्ति के साथ। (1250V चरण-इन वोल्टेज)