- 06
- Apr
តើធ្វើដូចម្តេចដើម្បីជ្រើសរើស Inverter thyristor សម្រាប់ induction melting furnace?
How to choose inverter thyristor for ឡចំហាយរលាយ?
1) ជ្រើសរើសយោងទៅតាមជួរប្រេកង់ប្រតិបត្តិការនៃឡចំហាយរលាយ;
The frequency is 100HZ—500HZ and the selected turn-off time is 20µs-45µs KK type thyristor.
The frequency is 500HZ—1000HZ and the selected turn-off time is 18μs-25μs KK type thyristor.
The frequency is 1000HZ—2500HZ and the selected turn-off time is 12μs-18μs KK type thyristor.
KKG-type thyristor with a frequency of 2500HZ—4000HZ and a selected turn-off time of 10µs-14µs.
The frequency is 4000HZ—8000HZ, and the selected turn-off time is 6μs—9μs KA type SCR.
2) ជ្រើសរើសយោងទៅតាមថាមពលទិន្នផលនៃឡចំហាយរលាយ;
According to the theoretical calculation of the parallel bridge inverter circuit, the current flowing through each thyristor is 0.455 times the total current. Considering that enough space is left, a thyristor with the same size as the rated current is usually selected.
thyristor 300A/1400V បច្ចុប្បន្នដែលបានជ្រើសរើសដែលមានថាមពលពី 50KW ទៅ 100KW ។ (វ៉ុលក្នុងដំណាក់កាល 380V)
thyristor ចរន្ត 500A/1400V ដែលបានជ្រើសរើសដែលមានថាមពល 100KW-250KW ។ (វ៉ុលក្នុងដំណាក់កាល 380V)
thyristor 800A/1600V បច្ចុប្បន្នដែលបានជ្រើសរើសដែលមានថាមពលចាប់ពី 350KW ដល់ 400KW ។ (វ៉ុលក្នុងដំណាក់កាល 380V)
thyristor 1500A/1600V បច្ចុប្បន្នដែលបានជ្រើសរើសដែលមានថាមពលពី 500KW ទៅ 750KW ។ (វ៉ុលក្នុងដំណាក់កាល 380V)
thyristor 1500A/2500V បច្ចុប្បន្នដែលបានជ្រើសរើសដែលមានថាមពលពី 800KW ទៅ 1000KW ។ (វ៉ុលក្នុងដំណាក់កាល 660V)
thyristor ចរន្ត 2000A/2500V ដែលបានជ្រើសរើសដែលមានថាមពល 1200KW-1600KW ។ (វ៉ុលក្នុងដំណាក់កាល 660V)
thyristor 2500A/3000V បច្ចុប្បន្នដែលបានជ្រើសរើសដែលមានថាមពលពី 1800KW ទៅ 2500KW ។ (វ៉ុលក្នុងដំណាក់កាល 1250V)