How to choose inverter thyristor for 유도 용해로?
1) 유도 용해로의 작동 주파수 범위에 따라 선택하십시오.
The frequency is 100HZ—500HZ and the selected turn-off time is 20µs-45µs KK type thyristor.
The frequency is 500HZ—1000HZ and the selected turn-off time is 18μs-25μs KK type thyristor.
The frequency is 1000HZ—2500HZ and the selected turn-off time is 12μs-18μs KK type thyristor.
KKG-type thyristor with a frequency of 2500HZ—4000HZ and a selected turn-off time of 10µs-14µs.
The frequency is 4000HZ—8000HZ, and the selected turn-off time is 6μs—9μs KA type SCR.
2) 유도 용해로의 출력 전력에 따라 선택하십시오.
According to the theoretical calculation of the parallel bridge inverter circuit, the current flowing through each thyristor is 0.455 times the total current. Considering that enough space is left, a thyristor with the same size as the rated current is usually selected.
선택된 전류 300A/1400V 사이리스터는 50KW에서 100KW 사이의 전력을 공급합니다. (380V 결상 전압)
500KW-1400KW의 전력을 가진 선택된 현재 100A/250V 사이리스터. (380V 결상 전압)
전력 범위가 800KW ~ 1600KW인 선택된 전류 350A/400V 사이리스터. (380V 결상 전압)
선택된 전류 1500A/1600V 사이리스터는 500KW에서 750KW 사이의 전력을 공급합니다. (380V 결상 전압)
선택된 전류 1500A/2500V 사이리스터는 800KW에서 1000KW 사이의 전력을 공급합니다. (660V 결상 전압)
2000KW-2500KW의 전력을 가진 선택된 현재 1200A/1600V 사이리스터. (660V 결상 전압)
선택된 전류 2500A/3000V 사이리스터는 1800KW에서 2500KW 사이의 전력을 공급합니다. (1250V 결상 전압)