Summary of Inspection and Repair of Induction Melting Furnace to Avoid Major Accidents
Summary of Inspection and Repair of Induction Melting Furnace to Avoid Major Accidents
Maintenance and repair items | Maintenance and repair content | Maintenance time and frequency | Remark | |
furnace
lining |
Whether the furnace lining has cracks |
Check for cracks in the crucible | Before the furnace starts every time | If the crack width is less than 22 mm , it is not necessary to repair it when chips and other things will not be embedded in the crack, and it can still be used. Otherwise, it needs to be patched before it can be used |
Repair of taphole | Observe whether there are cracks at the junction of the side avoiding furnace lining and the tap hole | At the time of tapping | If cracks appear, repair them | |
Furnace lining repair at furnace bottom and slag line | Visually observe whether the furnace lining at the bottom of the furnace and the slag line is locally corroded | After casting | If there is obvious corrosion, it needs to be repaired | |
feel
answer
String
lock up |
Visual inspection |
(1 ) Whether the insulation part of the coil is bruised or carbonized
(2 ) Is there any foreign compound attached to the surface of the coil? (3) Whether the insulating backing plate between the coils protrudes (4) Whether the assembly bolts of the tightening coil are loose |
1 time / day
1 time / day 1 time / day 1 time /3 months |
Purge with compressed air in the workshop
Tighten the bolts |
Coil compression screw | Visually check whether the coil compression screw is loose | 1 time / week | ||
rubber tube | (1) Whether there is water leakage at the rubber tube interface
(2 ) Check whether the rubber tube is cut |
1 time / day
1 time / week |
||
Coil anti-corrosion joint |
Remove the rubber hose and check the corrosion degree of the anti-corrosion joint at the coil end | 1 time /6 months | When this anti-corrosion joint corrodes more than 1/2 , it needs to be replaced with a new one. Usually changed every two years | |
Cooling water temperature at coil outlet | Under the conditions of rated molten iron volume and rated power, record the maximum and minimum values of the cooling water temperature of each branch of the coil | 1 time / day | ||
Dust removal | The compressed air in the workshop blows away the dust and molten iron splashes on the surface of the coil | 1 time / day | ||
Pickling | Pickling of sensor water pipes | 1 time /2 years | ||
Can
scratch sex guide String |
Water-cooled cable |
(1 ) Whether there is electricity leakage
(2 ) Check whether the cable is in contact with the furnace pit (3 ) Record the temperature of the cable outlet water under the rated power (4 ) Preventive measures taken to prevent accidents (5 ) Check whether the connecting bolts at the terminals are discolored |
1 time / day
1 time / day 1 time / day 1 time /3 years 1 time / day |
According to the number of tilts, determine the life of the water-cooled cable as three years, and need to be replaced after three years. If the bolt changes color, re-tighten it |
Maintenance and repair items | Maintenance and repair content | Maintenance time and frequency | Remark | |
furnace
cover
|
Dry cable |
(1) Eliminate dust on the insulating bakelite busbar splint
(2 ) Check whether the chain hanging the busbar splint is broken (3 ) Whether the copper foil of the bus bar is disconnected |
1 time / day
1 time / week 1 time / week |
When the area of the disconnected copper foil accounts for 10% of the conductive area of the bus, it needs to be replaced with a new bus |
Refractory castable | Visually inspect the thickness of the refractory pouring layer of the furnace cover lining | 1 time / day | When the thickness of the refractory castable remains 1/2 , the furnace cover lining must be rebuilt | |
Oil pressure furnace cover
|
(1 ) Whether there is leakage in the sealing part
(2 ) Leakage of piping (3 ) Leakage of high pressure pipe |
1 time / day
1 time / day 1 time / day |
If yes, repair it
Swap |
|
High pressure pipe | (1 ) Whether there are traces of molten iron scald on the high-pressure pipe, etc.
( 2 ) To ensure safety, exchange |
1 time / week
1 time /2 years |
||
Add lubricating oil |
(1 ) Manual type: Furnace cover fulcrum part
(2) Electric type: sprocket drive bearing for shaft adjustment chain for furnace cover wheel (3 ) Hydraulic type: guide bearing |
|||
pour
move
Oil
Cylinder |
Lower bearing and high pressure pipe of oil cylinder | (1 ) Whether there are traces of molten iron scald on the bearing part and the high-pressure pipe
(2 ) Oil leakage |
1 time / week
1 time / month |
Remove the cover for inspection |
Cylinder |
(1 ) Whether there is leakage in the sealing part
(2) Abnormal sound |
1 time / day
1 time / day |
When tilting the furnace, observe the cylinder block
When making sounds such as knocking on the cylinder, the bearings are mostly out of oil |
|
Tilting furnace limit switch |
(1) Action check
Press the limit switch by hand, the oil pump motor should stop running (2 ) Whether there is molten iron splashing on the limit switch |
1 time / week
1 time / week |
||
Add lubricating oil | All fuel ports | 1 time / week | ||
High pressure control
cabinet |
Appearance inspection inside the cabinet |
(1) Check the operation of each indicator light bulb
(2 ) Whether the parts are damaged or burned out (3 ) Clean the pan with compressed air in the workshop |
1 time / month
1 time / week 1 time / week |
|
Circuit breaker vacuum switch |
(1 ) The cleaning pass is a contact
The vacuum tube is milky white and fuzzy, the vacuum degree is reduced (2 ) Measuring electrode consumption |
1 time /6 months
1 time / month |
If the gap exceeds 6 mm, replace the vacuum tube |
|
Main switch cabinet |
Electromagnetic air switch |
(1 ) Roughness and wear of the main contact
(2 ) Come on
(3 ) Whether the fire extinguishing board is carbonized |
1 time /6 months
1 time /6 months
1 time /6 months |
When the roughness is severe, grind it with a file, sand skin, etc.
When the contact wear exceeds 2/3 , replace the contact Add spindle oil to each bearing and connecting rod Use sanding to remove the carbonized part
|
Maintenance and repair items | Maintenance and repair content | Maintenance time and frequency | Remark | |
Main switch cabinet | ( 4) Dust removal | 1 time / week | Clean with compressed air in the workshop, and wipe the dust on the insulators with a cloth | |
Insulation resistance | Use a 1000 volt megger to measure the main circuit and greater than 10M Ω | |||
Converter switch |
Transfer switch |
(1) Measure insulation resistance
(2 ) Rough switch main connector (3) The main circuit connecting bolts are loose and overheated |
1 time /6 months
1 time / month 1 time /3 months |
Between the conductor and the ground, use a 1000 volt megohmmeter to measure greater than
1M Ω Polish or exchange |
control
system
cabinet
tower |
Appearance inspection inside the cabinet | (1) Whether the components are damaged or burned out
(2 ) Whether the components are loose or fall off |
1 time / week
1 time / week |
|
Action test |
(1 ) Check whether the indicator light can be on
(2 ) Alarm circuit Action should be checked according to alarm conditions |
1 time / week
1 time / week |
||
Dust removal in the cabinet | Clean with compressed air in the workshop | 1 time / week | ||
Contactor for auxiliary machine |
(1) Check the roughness of the contact, if the roughness is severe, polish it smoothly with fine sand
(2) Exchange contacts Replace the contacts when they are badly worn |
1 time / 3 months
1 time /2 years |
Especially the frequently used contactor for tilting furnace lid | |
Transformer reactor | Check appearance | (1 ) Whether there is oil leakage
(2 ) Whether the insulating oil is added to the specified position |
1 time / week
1 time / week |
|
Transformer and reactor temperature | Check the daily thermometer indication, which is lower than the specified value | 1 time / week | ||
Sound and vibration | (1 ) Usually check by listening and touching
(2 ) Instrument measurement |
1 time / week
1 time / year |
||
Insulating oil withstand voltage test | Should meet the specified value | 1 time /6 months | ||
Tap changer | (1 ) Check whether the tap changeover is offset
(2 ) Check the roughness of the tap adapter |
1 time /6 months
1 time /6 months |
Use fine sand to polish and replace it with a new one when it is severely rough | |
Capacitor bank | Check appearance | (1 ) Whether there is oil leakage
(2 ) Whether each terminal screw is loose |
1 time / day
1 time / week |
If slack occurs , the terminal part will be discolored due to overheating |
Exchange capacitor contactor
Dust removal |
(1) The roughness of the contact
1 ) Use a file to smooth the rough part 2 ) When the wear is severe, replace the joint (2 ) The contact temperature rises Use compressed air in the workshop to clean the insulators with a cloth |
1 time /6 months
1 time / week 1 time / week |
At least 1 time / month |
|
The temperature around the capacitor bank | Measure with mercury thermometer | 1 time / day | Ventilated , so that the surrounding temperature does not exceed 40 deg.] C | |
Hydraulic device |
Hydraulic oil |
(1 ) Whether there is any change in the color of the oil at the height of the oil level displayed by the oil level gauge
(2) Check the amount of dust in the hydraulic oil and the quality of the oil (3) Measuring temperature |
1 time / week
1 time /6 months
1 time /6 months |
If the oil level drops , there is a leak in the circuit
When the quality is poor , change the oil |
pressure gauge | Whether the tilting pressure is different from usual, when the pressure drops, adjust the pressure to the normal value | 1 time / week |